KSA-2300Ex Explosion-proof Online Biogas Analyzer
Biogas Analyzers

KSA-2300Ex

Explosion-proof Online Biogas Analyzer

Model
KSA-2300Ex
Manufacturer
SENSORONIC
Category
Gas Analyzers › Biogas Analyzers

Parameters: CH4, CO2, H2S, O2

IndustriesEnergy & Biogas

Overview

KSA-2300Ex is an explosion-proof online biogas analyzer that simultaneously measures four gas components: CH4, CO2, H2S and O2.

With an Ex d IIC T6 explosion-proof design and IP65 aluminum enclosure, it can be used at biogas production facilities in explosion-hazard areas, and it has automatic sensor fault diagnosis.

Its modular sensor design makes calibration and maintenance easy, and continuous monitoring helps optimize process control.

Key Features

  • Simultaneous measurement of 4 gases: CH4, CO2, H2S, O2
  • Explosion-proof online biogas analysis system
  • Ex d IIC T6 explosion-proof design
  • IP65 aluminum enclosure
  • NDIR and electrochemical (ECD) sensors
  • Capable of measuring high-concentration H2S
  • Fast response within 15 s (T90)
  • Optimized biogas monitoring process
  • Automatic sensor fault diagnosis
  • Continuous monitoring for optimized process control
  • 4~20 mA analog output
  • RS-232 communication
  • Modular sensor design for easy calibration
  • Modular construction for easy maintenance
  • Automatic zero function

Measured Parameters

ParameterMeasuring Range
CH40~100%vol
CO20~50%vol
H2S0~1000/9999ppm
O20~25%vol

Measurement Performance

ParameterMethod · Accuracy · Resolution
CH4Method: NDIR · Accuracy: ±2%FS · Resolution: 0.01
CO2Method: NDIR · Accuracy: ±2%FS · Resolution: 0.01
H2SMethod: ECD · Accuracy: ±3%FS · Resolution: 1
O2Method: ECD · Accuracy: ±3%FS · Resolution: 0.01

Specifications

ManufacturerSENSORONIC
Measured gasesCH4, CO2, H2S, O2
MethodNDIR / ECD
Accuracy (CH4, CO2)±2%FS
Accuracy (H2S, O2)±3%FS
Repeatability≤1%
Response time (T90)Within 15 s
Gas flow rate0.7~1.2 L/min
Gas pressure2~50 kPa
Analog output4~20mA
CommunicationRS-232
Ingress protectionIP65 (aluminum enclosure)
Explosion-proof ratingEx d IIC T6
Automatic zero functionSupported
Sensor self-diagnosisSupported
Operating temperature-15℃ ~ +45℃
Operating humidity0~95%RH (non-condensing)
Ambient pressure80~120 kPa
Power supplyAC220V, 50Hz
Dimensions400×400×250 mm (H×W×D)
Weight140 kg

Applications

  • Biogas composition analysis of anaerobic digesters
  • Biogas engines and combined heat and power (CHP) plants
  • Landfill gas monitoring
  • Gas concentration monitoring of biogas flares
  • Hydrogen sulfide measurement at H2S scrubbers
  • Biomethane production and upgrading facilities
  • Biogas composition analysis at wastewater treatment plants
  • Biogas production facilities and process management in explosion-hazard areas