KSA-2000P Portable Biogas Analyzer
Biogas Analyzers

KSA-2000P

Portable Biogas Analyzer

Model
KSA-2000P
Manufacturer
SENSORONIC
Category
Gas Analyzers › Biogas Analyzers

Parameters: CH4, CO2, H2S, O2, H2

IndustriesEnergy & Biogas

Overview

KSA-2000P is a portable biogas analyzer that simultaneously measures five gas components: CH4, CO2, H2S, O2 and H2.

It features a 5-inch color touch screen, online gas concentration monitoring, 4~20 mA analog output, measurement data storage, and gas concentration alarms with alarm relay output.

With a modular design for easy calibration and a rugged portable build, it is well suited to on-site measurement at biogas production and treatment facilities such as anaerobic digesters, biogas engines/CHP and H2S scrubbers.

Key Features

  • Simultaneous measurement of 5 gases: CH4, CO2, H2S, O2, H2
  • NDIR, thermal conductivity (TCD) and electrochemical (ECD) sensors
  • High accuracy and stable analytical performance
  • Fast response within 10 s (T90)
  • 5-inch color touch-screen LCD display
  • Online gas concentration monitoring
  • 4~20 mA analog output
  • RS-232/RS-485 Modbus communication
  • Measurement data storage
  • Gas concentration alarm and alarm relay output
  • Modular design for easy calibration
  • Rechargeable DC 12 V battery
  • Rugged, portable industrial design
  • Suitable for biogas production and treatment facilities

Measured Parameters

ParameterMeasuring Range
CH40~50/100%vol
CO20~50/100%vol
H2S0~9999ppm
O20~25%vol
H20~100%vol

Measurement Performance

ParameterMethod · Accuracy · Resolution
CH4Method: NDIR · Accuracy: ±2%FS · Resolution: 0.01
CO2Method: NDIR · Accuracy: ±2%FS · Resolution: 0.01
H2SMethod: ECD · Accuracy: ±3%FS · Resolution: 1
O2Method: ECD · Accuracy: ±2%FS · Resolution: 0.01
H2Method: TCD · Accuracy: ±2%FS · Resolution: 0.1

Specifications

ManufacturerSENSORONIC
Measured gasesCH4, CO2, H2S, O2, H2
MethodNDIR / TCD / ECD
Accuracy (CH4, CO2, H2, O2)±2%FS
Accuracy (H2S)±3%FS
Repeatability≤1%
Response time (T90)Within 10 s
Display5-inch color touch-screen LCD
Gas flow rate0.7~1.2 L/min
Gas pressure2~50 kPa
CommunicationRS-232 / RS-485 Modbus Protocol
Analog output4~20mA
Alarm functionGas concentration alarm and alarm relay output
Data storageSupported
Operating temperature-15℃ ~ +45℃
Operating humidity0~95%RH
Ambient pressure80~120 kPa
Power supplyRechargeable DC 12 V battery
Dimensions300×185×180 mm (W×D×H)
Weight3 kg

Applications

  • Biogas composition analysis of anaerobic digesters
  • Biogas engines and combined heat and power (CHP) plants
  • Gas concentration analysis in chemical conversion processes
  • Clean Development Mechanism (CDM) projects
  • Gas concentration measurement at H2S scrubbers
  • Biomethane production and upgrading facilities
  • Biogas analysis in laboratories and testing institutes
  • Quality control and process monitoring of biogas production facilities