
Flue Gas (Stack) Analyzers
KSA-1100P
Portable Flue Gas Analyzer
- Model
- KSA-1100P
- Manufacturer
- SENSORONIC
- Category
- Gas Analyzers › Flue Gas (Stack) Analyzers
Parameters: CO, CO2, NO, SO2, O2
IndustriesEmission Monitoring
Overview
KSA-1100P is a portable emission gas analyzer using NDIR and electrochemical (ECD) measurement technologies, simultaneously measuring five gas components: CO, CO2, NO, SO2 and O2.
It supports a 5-inch color touch screen, RS-485 Modbus communication and a 4~20 mA analog interface, and its small, portable design makes it easy to move on site.
It is used for biomass gasification, waste-to-energy, landfill gas and industrial emission measurement.
Key Features
- Simultaneous measurement of 5 gases: CO, CO2, NO, SO2, O2
- NDIR and electrochemical (ECD) measurement technologies
- Fast response (T90 within 10 s)
- Real-time online gas concentration monitoring
- 5-inch color touch-screen LCD
- Automatic zero function
- High accuracy and stable analytical performance
- Modular sensor design for easy maintenance
- RS-485 Modbus communication
- 4~20 mA analog interface
- Small, portable design for easy field use
- Multiple measurement ranges available
- Suitable for industrial sites and emission monitoring
Measured Parameters
| Parameter | Measuring Range |
|---|---|
| CO | 0~200/2000ppm |
| CO2 | 0~25%vol |
| NO | 0~200ppm |
| SO2 | 0~200/2000ppm |
| O2 | 0~25%vol |
Measurement Performance
| Parameter | Method · Accuracy · Resolution |
|---|---|
| CO | Method: NDIR · Accuracy: ±2%FS · Resolution: 1ppm |
| CO2 | Method: NDIR · Accuracy: ±2%FS · Resolution: 0.01% |
| NO | Method: NDIR · Accuracy: ±2%FS · Resolution: 1ppm |
| SO2 | Method: NDIR · Accuracy: ±2%FS · Resolution: 1ppm |
| O2 | Method: ECD · Accuracy: ±2%FS · Resolution: 0.01% |
Specifications
| Manufacturer | SENSORONIC |
|---|---|
| Measured gases | CO, CO2, NO, SO2, O2 |
| Method | NDIR / ECD |
| Accuracy | ±2%FS |
| Resolution | CO, NO, SO2: 1ppm / CO2, O2: 0.01% |
| Repeatability | ≤2% |
| Response time (T90) | Within 10 s |
| Display | 5-inch color touch-screen LCD |
| Gas flow rate | 0.7~1.2 L/min |
| Gas pressure | 2~50 kPa |
| Communication | RS-485 Modbus |
| Analog interface | 4~20mA |
| Operating temperature | -15℃ ~ +45℃ |
| Operating humidity | 0~95%RH (non-condensing) |
| Ambient pressure | 80~120 kPa |
| Power supply | AC220V / 50Hz |
| Dimensions | 410×150×290 mm (L×W×H) |
| Weight | 5 kg |
Applications
- Exhaust gas analysis in biomass gasification
- Exhaust gas monitoring at waste-to-energy facilities
- Gas composition analysis of anaerobic digesters
- Landfill gas and exhaust gas monitoring
- Clean Development Mechanism (CDM) projects
- Coal gasification and pyrolysis processes
- Plasma gasification processes
- Biogas engines and combined heat and power (CHP) equipment
- Gas concentration analysis at wastewater treatment plants
- Gas measurement at industrial pollution control facilities
Related Products

Flue Gas (Stack) Analyzers
KSA-1100
Flue Gas Analyzer
Parameters: CO, CO2, NO, NO2, SO2, O2

Flue Gas (Stack) Analyzers
KSA-1000
Flue Gas Analyzer
Parameters: NO, NO2, SO2

Flue Gas (Stack) Analyzers
KSA-1000UV
UV Flue Gas Analyzer
Parameters: NO, NO2, SO2

Flue Gas (Stack) Analyzers
KSA-7000
Stack Gas Analyzer
Parameters: CO, CO2, H2S, NH3, O2, HCl, HF