KPA-3200 Greenhouse Gas Emission Analyzer
Flue Gas (Stack) Analyzers

KPA-3200

Greenhouse Gas Emission Analyzer

Model
KPA-3200
Manufacturer
SENSORONIC
Category
Gas Analyzers › Flue Gas (Stack) Analyzers

Parameters: CO2, CH4, N2O, CO, O2

Overview

KPA-3200 is a greenhouse gas emission analyzer using micro-flow NDIR and dual-beam NDIR measurement technologies, continuously and simultaneously measuring five gas components: CO2, CH4, N2O, CO and O2.

It measures low-concentration gases precisely and its low drift ensures stable long-term measurement, with a response time (T90) within 20 seconds. It provides digital and analog outputs, RS-232/RS-485 communication and built-in diagnostics.

It is used for greenhouse gas emission monitoring, emission analysis at power plants and combustion facilities, N2O emission analysis and performance evaluation of GHG abatement equipment.

Key Features

  • Simultaneous continuous measurement of 5 gases: CO2, CH4, N2O, CO, O2
  • Micro-flow NDIR measurement technology
  • Dual-beam NDIR sensor
  • Precise measurement of low-concentration gases
  • High accuracy and stable analytical performance
  • Low drift for stable long-term measurement
  • Fast response (T90 within 20 s)
  • Digital and analog signal output
  • RS-232 and RS-485 communication
  • 4~20 mA analog output
  • Built-in diagnostics for equipment status checks
  • Multiple measurement ranges available
  • Suitable for industrial sites and continuous gas monitoring systems

Measured Parameters

ParameterMeasuring Range
CO20~500ppm / 0~20%vol / 25~100%vol
CH40~1000ppm
N2O0~1000ppm
CO0~200/500ppm / 1~5%vol
O20~25%vol

Measurement Performance

ParameterMethod · Accuracy · Resolution
CO2Method: Micro-Flow NDIR / Dual Beam NDIR · Accuracy: ±1%FS / ±1%FS / ±2%FS · Resolution: 1ppm / 0.01% / 0.01%
CH4Method: NDIR · Accuracy: ±1%FS · Resolution: 1ppm
N2OMethod: NDIR · Accuracy: ±1%FS · Resolution: 1ppm
COMethod: Micro-Flow NDIR · Accuracy: ±1%FS / ±2%FS · Resolution: 1ppm / 0.001%
O2Method: ECD · Accuracy: ±2%FS · Resolution: 0.01%

Specifications

ManufacturerSENSORONIC
Measured gasesCO2, CH4, N2O, CO, O2
MethodMicro-Flow NDIR / Dual Beam NDIR / NDIR / ECD
Accuracy±1%FS ~ ±2%FS (varies by range)
RepeatabilityCO2, CH4, N2O, CO: ±≤1% / O2: ±≤2%
Response time (T90)Within 20 s
Gas flow rate0.7~1.2L/min
DiagnosticsBuilt-in
Communication and outputRS-232 / RS-485 / 4~20mA
Gas pressure2~50kPa
Operating temperature-15℃ ~ +45℃
Operating humidity0~95%RH (non-condensing)
Ambient pressure80~120kPa
Power supplyAC110~240V
Dimensions400×485×132mm (L×W×D)
Weight18kg

Applications

  • Greenhouse gas emission monitoring and gas composition analysis
  • Emission concentration analysis for power plants and combustion facilities
  • Nitrous oxide (N2O) emission analysis
  • Performance evaluation of greenhouse gas abatement equipment
  • Industrial continuous gas measurement systems
  • Emission measurement at industrial facilities and manufacturing processes
  • Carbon dioxide (CO2) and methane (CH4) concentration monitoring
  • Pollution control facilities and emission management
  • Gas analysis in research institutes and testing laboratories