Flue Gas (Stack) Analyzers
Gasboard-3800Plus
Portable Infrared Flue Gas Analyzer 3800Plus
- Model
- Gasboard-3800Plus
- Category
- Gas Analyzers › Flue Gas (Stack) Analyzers
Parameters: SO2, NO, CO, CO2, O2
IndustriesEmission Monitoring
Measurement PrincipleNDIR
Overview
Gasboard-3800Plus is a portable infrared flue gas analyzer for SO2, NO, CO, CO2 and O2, using dual-beam micro-flow NDIR sensors and a long-life electrochemical O2 sensor. The dual-beam design suppresses moisture and ambient temperature/pressure effects for stable low-concentration measurement, and it comes with a heated probe and gas conditioning unit.
Key Features
- PCT approved product based on micro-flow NDIR technology to measure low concentration gases. (US Authorization No.: US11079322).
- Unique dual beam NDIR micro-flow technology effectively solves the moisture interference to ensure intensity ratio of measurement signal and reference signal is not affected by the ambient temperature and pressure. Its stable performance is very suitable for low-concentration flue gas component monitoring.
- Non-dispersive NDIR and long life time electrochemical technology to ensure no cross-interference between the measurement gases, its high measurement accuracy and sensor life is longer.
- It is equipped with integrated sampling probe, heating tube, and imported gas conditioning device removes dust and moisture.
- Automatic calculation of air coefficient and combustion efficiency.
- Automatic storage of measurement data.
- Dot matrix printer and USB communication interface to print real-time and historical data, or directly export the stored data to the USB flash drive.
- Stainless steel heating type sampling probe, heating temperature up to 200℃.
- The probe is equipped with SIC filter element for quick replacement.
- Sampling probes are available in different lengths (1 or 2 meters) to suit various industrial applications.
- Heating tube has self-controlled temperature function to keep high temperature of 180℃, it can prevent SO2 gas condensation to loss value.
- Original imported diaphragm pump, flow rate ≤60L/h.
- Gas-water separator to separate liquid water in the sample gas.
- Original Peltier cooler removes gaseous water from sample gas.
- Equipped with corrosion-resistant and pressure-resistant heat exchanger and independent digital PID controller.
- After treating, sample gas dew point:≤4℃, dust accuracy: 0.1μm.
Measured Parameters
| Parameter | Measuring Range |
|---|---|
| SO2 | To be confirmed |
| NO | To be confirmed |
| CO | To be confirmed |
| CO2 | To be confirmed |
| O2 | To be confirmed |
Specifications
| Measurement Range | SO2/NO:(0~500~2000) mg/m3 / CO:(0~5000) mg/m3 / CO2/O2:(0~25)% |
|---|---|
| Accuracy | ±2%F.S. |
| Repeatability | ≤2% |
| Response Time | ≤30S |
| Warm-up Time | 5min |
| Stability | ≤2%F.S./24h |
| Flowrate | (0.7~1.2)L/min |
| Size | 275mm*470mm*175mm |
| Weight | 7.5kg |
| Power Supply | 100~240VAC 80W |
| Display | LCD |
Applications
- Stack and boiler emission measurement
- Low-concentration emission measurement
Related Products

Flue Gas (Stack) Analyzers
KSA-1100
Flue Gas Analyzer
Parameters: CO, CO2, NO, NO2, SO2, O2

Flue Gas (Stack) Analyzers
KSA-1100P
Portable Flue Gas Analyzer
Parameters: CO, CO2, NO, SO2, O2

Flue Gas (Stack) Analyzers
KSA-1000
Flue Gas Analyzer
Parameters: NO, NO2, SO2

Flue Gas (Stack) Analyzers
KSA-1000UV
UV Flue Gas Analyzer
Parameters: NO, NO2, SO2