Gasboard-3800GHG Portable Greenhouse Gas Emission Analyzer
Flue Gas (Stack) Analyzers

Gasboard-3800GHG

Portable Greenhouse Gas Emission Analyzer

Model
Gasboard-3800GHG
Category
Gas Analyzers › Flue Gas (Stack) Analyzers

Parameters: CO2, CH4, N2O, CO

Measurement PrincipleNDIR

Overview

Gasboard-3800GHG is a portable greenhouse gas emission analyzer using patented micro-flow NDIR dual-chamber sensors to measure CO2, CH4, N2O and CO in flue gas, with ranges from 200 ppm and accuracy up to 1% F.S. With an integrated heated probe, portable conditioning unit and optional temperature, pressure and flow measurement, it can calculate emission rates and totals.

Key Features

  • PCT approved product based on micro-flow NDIR technology to measure low concentration gases. (US Authorization No.: US11079322);
  • One analyzer can simultaneously and continuously measure up to five gases such as CO2, CH4, N2O, CO and O2;
  • CO2, CH4, N2O, CO can choose the patented Microflow NDIR technology, the range can be as low as 200ppm, accuracy up to 1%F.S.;
  • Small drift, anti-moisture interference, good long-term stability;
  • Dual beam NDIR technology can be used to measure CO2 and CO for flexible collocation for medium and high concentration measurement requirements;
  • Both digital and analog signal output functions, simple data management;
  • Portable instrument, and equipped with high-performance sampling probe and pretreatment device.

Measured Parameters

ParameterMeasuring Range
CO2To be confirmed
CH4To be confirmed
N2OTo be confirmed
COTo be confirmed

Specifications

Measuring componentsCO2, CH4, N2O, CO, O2
Measuring PrincipleMicro-flow NDIR: CO2/CH4/N2O/CO / Dual beam NDIR: CO2(high range), CO(Middle or high range) / ECD: O2
Measurement rangeCO2: / Micro-flow NDIR: Range 0-500ppm, resolution: 1ppm; / Micro-flow NDIR: Range 20%, resolution: 0.01%; / Dual beam NDIR: Range 25%-100%, resolution: 0.01% / CH4: / Range 1000ppm, resolution: 1ppm / N2O: / Range 1000ppm, resolution: 1ppm / CO: / Micro-flow NDIR: Range 200-500ppm, resolution: 1ppm; / Dual beam NDIR: Range 1-5%, resolution: 0.001% / O2: / Range 0-25%, resolution: 0.01%
Measurement PrecisionMicro-flow NDIR measurement CO2/CH4/N2O/CO: ±1%F.S. / Dual beam NDIR measurement CO2/CO: ±2%F.S. / Electrochemical measurement O2: ±2%F.S.
Repeatability≤±1%
Response TimeT90 <25s
Flow rate(0.7-1.2) L/min
Inlet gas pressure(2-50) kPa
Output signalUSB,OR Dot matrix printer
Power supply100~240VAC, 150W
Diagnosis FunctionEquipped with self-diagnosis function to check sensor status

Applications

  • Greenhouse gas emission measurement
  • Emission rate and total emission calculation