Flue Gas (Stack) Analyzers
Gasboard-3800GHG
Portable Greenhouse Gas Emission Analyzer
- Model
- Gasboard-3800GHG
- Category
- Gas Analyzers › Flue Gas (Stack) Analyzers
Parameters: CO2, CH4, N2O, CO
IndustriesEmission Monitoring
Measurement PrincipleNDIR
Overview
Gasboard-3800GHG is a portable greenhouse gas emission analyzer using patented micro-flow NDIR dual-chamber sensors to measure CO2, CH4, N2O and CO in flue gas, with ranges from 200 ppm and accuracy up to 1% F.S. With an integrated heated probe, portable conditioning unit and optional temperature, pressure and flow measurement, it can calculate emission rates and totals.
Key Features
- PCT approved product based on micro-flow NDIR technology to measure low concentration gases. (US Authorization No.: US11079322);
- One analyzer can simultaneously and continuously measure up to five gases such as CO2, CH4, N2O, CO and O2;
- CO2, CH4, N2O, CO can choose the patented Microflow NDIR technology, the range can be as low as 200ppm, accuracy up to 1%F.S.;
- Small drift, anti-moisture interference, good long-term stability;
- Dual beam NDIR technology can be used to measure CO2 and CO for flexible collocation for medium and high concentration measurement requirements;
- Both digital and analog signal output functions, simple data management;
- Portable instrument, and equipped with high-performance sampling probe and pretreatment device.
Measured Parameters
| Parameter | Measuring Range |
|---|---|
| CO2 | To be confirmed |
| CH4 | To be confirmed |
| N2O | To be confirmed |
| CO | To be confirmed |
Specifications
| Measuring components | CO2, CH4, N2O, CO, O2 |
|---|---|
| Measuring Principle | Micro-flow NDIR: CO2/CH4/N2O/CO / Dual beam NDIR: CO2(high range), CO(Middle or high range) / ECD: O2 |
| Measurement range | CO2: / Micro-flow NDIR: Range 0-500ppm, resolution: 1ppm; / Micro-flow NDIR: Range 20%, resolution: 0.01%; / Dual beam NDIR: Range 25%-100%, resolution: 0.01% / CH4: / Range 1000ppm, resolution: 1ppm / N2O: / Range 1000ppm, resolution: 1ppm / CO: / Micro-flow NDIR: Range 200-500ppm, resolution: 1ppm; / Dual beam NDIR: Range 1-5%, resolution: 0.001% / O2: / Range 0-25%, resolution: 0.01% |
| Measurement Precision | Micro-flow NDIR measurement CO2/CH4/N2O/CO: ±1%F.S. / Dual beam NDIR measurement CO2/CO: ±2%F.S. / Electrochemical measurement O2: ±2%F.S. |
| Repeatability | ≤±1% |
| Response Time | T90 <25s |
| Flow rate | (0.7-1.2) L/min |
| Inlet gas pressure | (2-50) kPa |
| Output signal | USB,OR Dot matrix printer |
| Power supply | 100~240VAC, 150W |
| Diagnosis Function | Equipped with self-diagnosis function to check sensor status |
Applications
- Greenhouse gas emission measurement
- Emission rate and total emission calculation
Related Products

Flue Gas (Stack) Analyzers
KSA-1100
Flue Gas Analyzer
Parameters: CO, CO2, NO, NO2, SO2, O2

Flue Gas (Stack) Analyzers
KSA-1100P
Portable Flue Gas Analyzer
Parameters: CO, CO2, NO, SO2, O2

Flue Gas (Stack) Analyzers
KSA-1000
Flue Gas Analyzer
Parameters: NO, NO2, SO2

Flue Gas (Stack) Analyzers
KSA-1000UV
UV Flue Gas Analyzer
Parameters: NO, NO2, SO2