Gasboard-9805 Portable Emission Measurement System (PEMS)
Automotive Exhaust Gas Analyzers

Gasboard-9805

Portable Emission Measurement System (PEMS)

Model
Gasboard-9805
Category
Gas Analyzers › Automotive Exhaust Gas Analyzers

Parameters: NO, NO2, THC, CO, CO2, PN/PM, Exhaust flow

IndustriesAutomotive

Overview

Gasboard-9805 is a portable emissions measurement system (PEMS) for real-driving tests, combining PEMS-GAS (CO, CO2, THC, NO, NO2), PEMS-PN and PEMS-EFM exhaust flow modules with GPS and ambient sensors. Time-aligned data and total mass emission reports meet RDE requirements for on-road and off-road vehicles.

Key Features

  • Self-developed gas analysis technologies including Infrared NDIR, UV-DOAS and so on.
  • Modular design, flexible to use.
  • Excellent performance meets high measurement standards.
  • Easy operation, supports testing process guidance, data storage and report generation functions.
  • More than 4 hours endurance of the built-in battery, no external battery needed supports complete real driving emission pollutant test.
  • Great environmental adaptability, not affect by vehicle vibration, heavy pressure, ambient temperature and humidity change.

Measured Parameters

ParameterMeasuring Range
NOTo be confirmed
NO2To be confirmed
THCTo be confirmed
COTo be confirmed
CO2To be confirmed
PN/PMTo be confirmed
Exhaust flowTo be confirmed

Specifications

RangeC0:0~5%; C02:0~20%; N0:0~3000ppm; N02:0~1000ppm; THC:0~9999ppm
ResolutionCO, C02: 0.01% / NO, N02, THC: 1ppm
Precision≤1%F.S.
Accuracy<±2% of reading or ±0.3% F.S., whichever is greater
Sensor response time T10-90<2.5s
System response time T0-90≤10s
Zero drift (4 hours)CO:≤±50ppm; CO2≤±0.10%; NO, N02≤5ppm; THC≤2%F.S.
Span drift (4 hours)CO: ≤2% of reading or ≤±50ppm, whichever is greater; / CO2: ≤2% of reading or ±0.1%, whichever is greater; / NO, NO2: ≤2% reading or ≤5ppm, whichever is greater / THC≤2%F.S.
Working environment temperature(5~40) ℃
Power supply24V, maximum power consumption 240W
CommunicationRS485,WIFI,RJ-45 Ethernet
Range600~1.3*10^9#/cm3
Particle size range23nm~2500nm
Rise time T10-90≤3s
Range10~600kg/h; 100~2000kg/h;200~4000kg/h
Discharge temperature-5~500℃
Accuracy<(±2% reading)or(±0.5%F.S.) / or (±1.0% of the maximum flow rate of the calibrated EFM) whichever is greater
Precision<1%F.S.
Linearity|Xmin*a1-1+a0|≤3%max, slope a1:0.97~1.03, / standard deviation SEE≤2%max, / determination coefficient r2≥0.990
Rise time T10-90<1s
Response time<3s

Applications

  • Real-driving emission (RDE) testing
  • Heavy-duty and light-duty vehicle emission measurement
  • Non-road mobile machinery emission measurement