Air scan Particulate Matter & Indoor Air Quality Monitor (Fixed / Portable)
Indoor Air Quality Monitors

Air scan

Particulate Matter & Indoor Air Quality Monitor (Fixed / Portable)

Model
Air scan
Manufacturer
SENSORONIC
Category
Air Quality Monitors › Indoor Air Quality Monitors

Parameters: PM2.5, PM10, CO2, HCHO, TVOC (optional: CO, NO2, O3)

Overview

Air scan is a combined particulate matter and indoor air quality monitor that measures regulated indoor parameters such as PM2.5, PM10, CO2, HCHO and TVOC at the same time. Its accuracy of over 90% has been certified by an accredited institute, and it achieved Grade 1 in the performance evaluation of simplified PM monitors.

Additional sensors such as CO, NO2, O3, SO2 and H2S can be selected and installed as required. Real-time readings are shown on a 3.5-inch color touch screen, and the logging interval can be set from 6 seconds to 1 hour.

With Wi-Fi, Ethernet, LTE, RS232/485 and USB communication, it supports real-time continuous measurement and remote monitoring, and has a built-in calibration function.

Key Features

  • Grade 1 in the performance evaluation of simplified PM monitors, with IoT technology
  • Combined particulate matter and indoor air quality monitor
  • Simultaneous measurement of regulated indoor air quality parameters
  • High accuracy of over 90%, certified by an accredited institute
  • User-configurable logging interval
  • Additional measurement items can be selected and installed
  • Built-in calibration function
  • Fast response time
  • Real-time continuous measurement and monitoring
  • Wi-Fi and Ethernet
  • RS232/485, USB

Measured Parameters

ParameterMeasuring Range
PM2.50~1,000μg/m³
PM100~1,000μg/m³
CO20~5,000ppm or 10,000ppm
HCHO0~2,500μg/m³ or / 12,500μg/m³
TVOC0~2,500μg/m³ or 23,000μg/m³
Temperature-40~125℃
Humidity0~100%RH

Measurement Performance

ParameterMethod · Accuracy · Resolution
PM2.5Method: Light scattering · Accuracy: 0~35μg/m³: ±5μg/m³ / 36~100μg/m³: ±10μg/m³ / 101~1,000μg/m³: ±10% reading · Resolution: 1μg/m³
PM10Method: Light scattering · Accuracy: 0~100μg/m3: ±15μg/m³ / 101~1000ug/m3: ±15% reading · Resolution: 1μg/m³
CO2Method: NDIR · Accuracy: ±2%FS · Resolution: 1ppm
HCHOMethod: Electrochemical · Accuracy: ±3%FS · Resolution: 0.001ppm
TVOCMethod: MOS / *Option: PID 10.6 eV · Accuracy: ±5%FS · Resolution: 0.001ppm

Specifications

ManufacturerSENSORONIC
Optional parametersCO, NO2, O3, SO2, H2S, etc.
Display3.5-inch TFT color LCD touch screen
Real-time reading display1 s (6-second average)
Averaging / logging interval6 s, 1 min, 5 min, 10 min, 30 min, 1 h (user-configurable)
CommunicationRS232/485, USB, Wi-Fi, Ethernet, LTE / *Option: alarm color lamp (color changing)
Flow rate600cc/min
Operating environmentTemperature: -20~60℃, Humidity: 0~95%RH
Dimensions110mm(W) x 160mm(H) x 55mm(D)
Power supplyDC 12 V or 12 V adapter
Weight900g