PM2105L Low Power Particle Sensor
Industrial Sensors & Transmitters

PM2105L

Low Power Particle Sensor

Model
PM2105L
Category
Flow, Pressure & Process Instruments › Industrial Sensors & Transmitters

Parameters: PM1.0, PM2.5, PM10

Overview

PM2105L is a low-power indoor laser particle sensor outputting PM1.0, PM2.5 and PM10 in μg/m³, suited to battery-powered products, with UART, I²C or PWM output and RoHS/REACH compliance.

Key Features

  • Low power suit for battery supply application
  • Real-time output PM1.0, PM2.5, PM10 in μg/m3 available
  • High accuracy, high sensitive and quick response
  • Signal output optional: UART, I²C, PWM
  • RoHS and Reach compliant
  • Air inlet and outlet on different side

Measured Parameters

ParameterMeasuring Range
PM1.00~1000 μg/m³
PM2.50~1000 μg/m³
PM100~1000 μg/m³

Specifications

Operating principleLaser scattering
Measured particle size0.3μm~10μm
Measurement range0~1000μg/m³
Resolution1μg/m³
Working condition-10°C ~ 60°C, 0-95%RH (non-condensing)
Storage condition-40°C ~ 80°C, 0-95%RH (non-condensing)
Measurement accuracy for PM1.0&PM2.50 ~100μg/m³, ±10μg/m³ / >100μg/m³, ±10% of reading / Condition: 25±2℃, 50±10%RH, / Reference instrument: GRIMM, / Dust source: Cigarette
Measurement accuracy for PM100 ~100μg/m³, ±30μg/m³ / 101 ~1000μg/m³, ±30% of reading / Condition: 25±2℃, 50±10%RH, / Reference instrument: GRIMM / Dust source: Cigarette
Response time1 sec
First time to reliable reading4 sec
Power supplyDC 5V±0.1V / Ripple wave<50 mV
Working current<53 mA
Standby current<5 mA
Dimensions42×35×23.7 mm
Digital output 1 (default)UART_TTL_3.3V(default) / I²C_3.3V/5V(default)
Digital output 2PWM (customized)
Output methodDefault by active output after powering on, sampling time interval should be over 1,000 ms
MTTF37,297 hrs (continuous turn on)

Applications

  • IAQ applications
  • Fresh air systems
  • Air quality monitors