Process Gas Analyzers
Gasboard-9031EX
Infrared Syngas Analysis System (Ex-proof)
- Model
- Gasboard-9031EX
- Category
- Gas Analyzers › Process Gas Analyzers
Parameters: CO, CO2, CH4, H2, O2, C2H2, C2H4, CnHm, Calorific value
IndustriesIndustrial Process
Measurement PrincipleNDIR
Overview
Gasboard-9031EX is an explosion-proof (Ex d IIC T4 Gb) online syngas monitoring system measuring CO, CO2, CH4, H2, O2, C2H2, C2H4, CnHm and calorific value. A heated stainless probe with auto-purge, two-stage filtration and cooling, and PLC automation enable 24/7 unattended monitoring in furnaces, metallurgy, CDQ and chemical plants.
Key Features
- Multi-Gas Measurement: Simultaneously detects CO, CO₂, CH₄, H₂, O₂, C₂H₂, C₂H₄, CnHm and calculates heat value.
- Robust Sampling Probe: Stainless steel, heated dry-extraction design with auto-purge function,ensures reliable operation in dusty environments.
- Dual-Stage Filtration & Cooling: Removes moisture and particles to ensure stable long-term performance of the analyzer.
- PLC-Controlled Operation: Fully automated sampling, backflushing, and drainage, enableing 24/7 unattended monitoring.
- High Safety Standards for Hazardous Areas: Certified with Ex d IIC T4 Gb explosion-proof rating, making it safe for use in flammable and potentially explosive environments.
Measured Parameters
| Parameter | Measuring Range |
|---|---|
| CO | To be confirmed |
| CO2 | To be confirmed |
| CH4 | To be confirmed |
| H2 | To be confirmed |
| O2 | To be confirmed |
| C2H2 | To be confirmed |
| C2H4 | To be confirmed |
| CnHm | To be confirmed |
| Calorific value | To be confirmed |
Specifications
| Measurement Components | CO, CO2, CH4, H2, O2, CnHm, C2H2, C2H4 |
|---|---|
| Measurement Principle | CO/CO2/CH4/C2H2/C2H4/CnHm: NDIR; H2: TCD; O2: ECD |
| Measurement Range * | CO/CO2/CH4/H2:(0~100)% / O2: (0~25)%; C2H2/C2H4/CnHm:(0~10)% (optional) |
| Accuracy | CO/CO2/CH4/C2H2/C2H4/CnHm: ±1%F.S. / O2/H2: ±2%F.S. |
| Resolution | 0.01% |
| Repeatability | ≤±1%F.S. |
| Response Time | T90<15s (NDIR) |
| Inlet Flow Rate | 0.7~1.2L/min |
| Inlet Gas Pressure | 2~50kPa |
| Sampling Gas Condition | No dust, no vapor, no tar |
| Ex-proof Grade | Ex d lIC T4 Gb |
| Dimension(L*W*H) | H1600 x W700 x D600 mm |
| Weight | 250kg |
| Pretreatment | Sampling probe with back-purge + heated tube + two stage filters + condenser |
| Communication | RS-485/RS-232;4~20mA;Ethernet |
| Power Supply | AC110/AC220V±40V,50/60Hz |
| Display | LCD |
| Function | Features self-diagnosis functionality, allowing online checking of sensor status |
Applications
- Heat treatment furnace atmosphere control
- Metallurgical processes
- CDQ systems
- Syngas production
- Hydrogen production
- Petrochemical refining
Related Products

Process Gas Analyzers
KSA-3500
Syngas Analyzer
Parameters: CO, CO2, CH4, CnHm, C2H2, C2H4, H2, O2

Process Gas Analyzers
KSA-3100
Syngas Analyzer
Parameters: CO, CO2, CH4, CnHm, C2H2, C2H4, H2, O2

Process Gas Analyzers
KSA-3100P
Portable Natural Gas Analyzer
Parameters: CO, CO2, CH4, CnHm, C2H2, C2H4, H2, O2

Process Gas Analyzers
KSA-3000
Syngas Analyzer
Parameters: CO, CO2, CH4, H2, O2