Gasboard-9031EX Infrared Syngas Analysis System (Ex-proof)
Process Gas Analyzers

Gasboard-9031EX

Infrared Syngas Analysis System (Ex-proof)

Model
Gasboard-9031EX
Category
Gas Analyzers › Process Gas Analyzers

Parameters: CO, CO2, CH4, H2, O2, C2H2, C2H4, CnHm, Calorific value

Measurement PrincipleNDIR

Overview

Gasboard-9031EX is an explosion-proof (Ex d IIC T4 Gb) online syngas monitoring system measuring CO, CO2, CH4, H2, O2, C2H2, C2H4, CnHm and calorific value. A heated stainless probe with auto-purge, two-stage filtration and cooling, and PLC automation enable 24/7 unattended monitoring in furnaces, metallurgy, CDQ and chemical plants.

Key Features

  • Multi-Gas Measurement: Simultaneously detects CO, CO₂, CH₄, H₂, O₂, C₂H₂, C₂H₄, CnHm and calculates heat value.
  • Robust Sampling Probe: Stainless steel, heated dry-extraction design with auto-purge function,ensures reliable operation in dusty environments.
  • Dual-Stage Filtration & Cooling: Removes moisture and particles to ensure stable long-term performance of the analyzer.
  • PLC-Controlled Operation: Fully automated sampling, backflushing, and drainage, enableing 24/7 unattended monitoring.
  • High Safety Standards for Hazardous Areas: Certified with Ex d IIC T4 Gb explosion-proof rating, making it safe for use in flammable and potentially explosive environments.

Measured Parameters

ParameterMeasuring Range
COTo be confirmed
CO2To be confirmed
CH4To be confirmed
H2To be confirmed
O2To be confirmed
C2H2To be confirmed
C2H4To be confirmed
CnHmTo be confirmed
Calorific valueTo be confirmed

Specifications

Measurement ComponentsCO, CO2, CH4, H2, O2, CnHm, C2H2, C2H4
Measurement PrincipleCO/CO2/CH4/C2H2/C2H4/CnHm: NDIR; H2: TCD; O2: ECD
Measurement Range *CO/CO2/CH4/H2:(0~100)% / O2: (0~25)%; C2H2/C2H4/CnHm:(0~10)% (optional)
AccuracyCO/CO2/CH4/C2H2/C2H4/CnHm: ±1%F.S. / O2/H2: ±2%F.S.
Resolution0.01%
Repeatability≤±1%F.S.
Response TimeT90<15s (NDIR)
Inlet Flow Rate0.7~1.2L/min
Inlet Gas Pressure2~50kPa
Sampling Gas ConditionNo dust, no vapor, no tar
Ex-proof GradeEx d lIC T4 Gb
Dimension(L*W*H)H1600 x W700 x D600 mm
Weight250kg
PretreatmentSampling probe with back-purge + heated tube + two stage filters + condenser
CommunicationRS-485/RS-232;4~20mA;Ethernet
Power SupplyAC110/AC220V±40V,50/60Hz
DisplayLCD
FunctionFeatures self-diagnosis functionality, allowing online checking of sensor status

Applications

  • Heat treatment furnace atmosphere control
  • Metallurgical processes
  • CDQ systems
  • Syngas production
  • Hydrogen production
  • Petrochemical refining