Parameters: CO, CO2, H2S, H2O, O2, CH4

Measurement PrincipleTDLAS

Overview

Gasboard-3500 is a wall-mounted online TDLAS analyzer measuring CO, CO2, H2S, H2O, O2 and CH4 from ppm to percent levels without cross-interference or frequent calibration. Ex dIICT6 Gb rated with no moving parts and self-diagnostics, it serves natural gas processing, petrochemicals, refining, power and biomethane upgrading.

Key Features

  • High Precision Detection: Utilizes TDLAS (Tunable Diode Laser Absorption Spectroscopy) technology for high selectivity, sensitivity, and stability.
  • Flexible Measurement Capability: Precise measurement of CO, CO₂, H₂S, O₂, and CH₄ with measurement range from ppm to 100%.
  • Robust Industrial Design: Ex dIICT6 Gb rated, suitable for harsh environments in oil & gas, petrochemical, and power generation industries.
  • Long-Term Reliability: No moving parts, minimal drift, and integrated self-diagnostics ensure long-term reliability.
  • Smart Data Management: Analog and serial outputs for remote monitoring.

Measured Parameters

ParameterMeasuring Range
COTo be confirmed
CO2To be confirmed
H2STo be confirmed
H2OTo be confirmed
O2To be confirmed
CH4To be confirmed

Specifications

Measured GasMeasurement range | Accuracy | Resolution
O20-500ppm | ±2%FS | 1ppm
0-1000ppm±2%FS
0-5000ppm±2%FS
0-5%±2%FS | 0.01%
0-25%±1%FS
0-100%±0.5%FS
CO0-500ppm | ±2%FS | 0.1ppm
0-1000ppm±1%FS
0-5%±2%FS | 0.01%
0-25%±1%FS
0-100%±1%FS
CO20-1000ppm | ±2%FS | 0.1ppm
0-5%±2%FS | 0.01%
0-25%±1%FS
0-100%±1%FS
H2S0-1000ppm | ±2%FS | 0.1ppm
0-1%±2%FS | 0.01%
CH40-100ppm | ±2%FS | 0.1ppm
0-1000ppm±1%FS
0-5%±2%FS | 0.01%
0-25%±1%FS
0-100%±1%FS
H2O0-50ppm | ±2%FS | 0.1ppm
Response TimeT90<40s (after completely warm up)
Inlet Flow Rate0.7~1.2L/min
Inlet Gas Pressure2~50kPa
Sampling Gas ConditionNo dust, no tar,no vapor (when measure CO, CO2, O2, CH4, H2S)
Ambient Temperature0-50℃
Ambient Pressure86-106kpa
Relative Humidity5-85% RH non-condensing
Dimension (L*W*H)H400 x W400 x D250 mm
Weight9kg
CommunicationRS-485/RS-232, 4~20mA
Power SupplyAC220V, 50Hz
DisplayLCD
Ex-proof RatingEx d ⅡC T6
FuctionBuilt-in zeroing air pump for automatic air zeroing; with self-diagnosis function for online sensor status checking

Applications

  • Natural gas processing
  • Petrochemical plants
  • Oil refineries
  • Power generation
  • Biogas and biomethane upgrading