Gas Leak Detectors
Gasboard-2063
NMP Gas Leakage Detector
- Model
- Gasboard-2063
- Category
- Gas Detectors & Alarms › Gas Leak Detectors
Parameters: NMP
IndustriesBattery Manufacturing
Measurement PrincipleNDIR
Overview
Gasboard-2063 is an NDIR NMP leak detector for lithium-ion battery coating and drying processes, with an integrated explosion-proof body (Ex dbIIC T3 Gb), self-calibration, strong anti-interference, tolerance up to 160℃ and a life of 5+ years.
Key Features
- Non-dispersive infrared technology (NDIR), high accuracy.
- Self-calibration, maintenance-free.
- Strong anti-interference ability, long life(≥5 years).
- Explosion-proof structure, Ex dbIIC T3 Gb explosion-proof grade.
- High temperature resistance, up to 160℃
Measured Parameters
| Parameter | Measuring Range |
|---|---|
| NMP | 0~100 %LEL |
Specifications
| Operating Principle | Non-dispersive infrared (NDIR) |
|---|---|
| Detection Gas Object | NMP GAS |
| Concentration Display | 7-segment LED (4 digits) |
| Detection Range | 0-100%LEL |
| Resolution | 0.1% LEL |
| Sampling Method | Furnace differential pressure air intake |
| Alarm Setting Value | 15%LEL~50%LEL (default 25%LEL, adjustable) |
| External Output | Gas concentration signal/alarm contact |
| Communication | DC 4~20mA (resistive load below 300Ω), RS485 (default 9600 baud rate) |
| Alarm Accuracy | ±5%LEL@15%LEL~50%LEL |
| Alarm Delay | T90<30s@15%LEL~50%LEL |
| Alarm Contact Capacity | 250 VAC*0.2A/30 VDC*1.5A(Impedance load) |
| Alarm Action | Automatic reset |
| Operating Voltage | 24 VDC±10% |
| Average Operating Current | <1.0A(@25℃,24VDC) |
| Warm-up Time | ≤30min |
| Operating Temperature | Measured gas temperature: 0~160℃ (usually); / Meter working temperature: 0~60℃ (usually) |
| Operating Humidity | <95%RH (no condensing) |
| Lifetime | ≥5 years |
| Structure | Furnace direct plug-in |
| Explosion-proof structure | Flameproof structure |
| Explosion-proof grade | Ex db IIC T3 Gb |
| Dimensions/weight | 418mm*178mm*110mm/about 6kg |
Applications
- Lithium-ion battery coating and drying
- Cleanroom monitoring