AM1002 Integrated Air Quality Sensor Module AM1002
Industrial Sensors & Transmitters

AM1002

Integrated Air Quality Sensor Module AM1002

Model
AM1002
Category
Flow, Pressure & Process Instruments › Industrial Sensors & Transmitters

Parameters: PM, VOC, Temperature, Humidity

Overview

AM1002 is an integrated air quality module measuring particles (PM1.0, PM2.5, PM10 by laser scattering), VOC (MOX sensor sensitive to formaldehyde, benzene, ethanol and more), temperature and humidity. Temperature compensation and matrix calibration provide accuracy and consistency in a compact package.

Key Features

  • 4 in 1 sensor module which integrated particle, VOC and RH&T.
  • Real time PM1.0 PM2.5 and PM10 output simultaneously.
  • High accuracy, high sensitive and quick response.
  • Temperature compensation algorithm.
  • Matrix calibration technology and optimized algorithm, for high accuracy and consistency.
  • Long lifespan and high stability.
  • Small size, compact structure, easy to install.

Measured Parameters

ParameterMeasuring Range
PM0~5000 μg/m³
VOC0~10 ppm
Temperature-20~70 °C
Humidity0~99 %RH

Specifications

Measurement rangeParticle: 0~5000μg/m³ / VOC: 0~10ppm / Temperature: -20℃~70℃ / Humidity: 0~99%RH
PM accuracyPM1.0/PM2.5: 0~100μg/m³ : ±10μg/m³ , 101~500μg/m³ : ±10% of reading / PM10: 0~100μg/m³ : ±25μg/m³ ,101~500μg/m³: ±25% of reading / (GRIMM, 25±2℃, 50 ±10%RH)
VOC consistencyTypical/Max: 200ppb/250ppb OR 20%/25%, whichever is larger
Temperature accuracy0°C ~ 40°C: ±1°C
Humidity accuracyTypical/Max: ±5%/±8% @5%-95%RH
Working condition-20℃~60℃, 0~95%RH(non-condensing)
Storage condition-40°C ~ 80°C, 0-95%RH (non-condensing)
Power supplyDC 5V±0.1V; ripple wave <50mV
Working current<100mA
Signal outputUART_TTL
DimensionW38*H35*D12 (mm)

Applications

  • IAQ applications
  • Fresh air systems
  • Fresh air system controllers
  • Air quality monitors